XLTR-1000
2-Port RS-485 gateway.
Modbus RTU, BACnet MS/TP, Metasys N2, Siemens FLN, Generic Serial, M-Bus, DMX-512, Toshiba, Sullair, TCS Basys, A.O. Smith, MSA Chillgard, and more.
This product has been discontinued and is no longer available for sale.
Please use our Mirius gateway as a direct replacement.

The XLTR-1000 Gateway allows data to be translated between two RS-485 networks with minimal configuration requirements. The gateway acts as a protocol converter/translator to allow complex interchanges of data and create a bridge between otherwise incompatible networks.
The XLTR-1000 provides two RS-485 ports (4-wire terminal block style). The RS-485 ports support multiple serial protocols, all of which are included free of charge.
Configuration is performed using the ICC Configuration Studio software via a USB connection. In addition to updating the gateway's configuration and firmware, the USB connection can also be used to monitor and command real-time data, diagnose communication issues, capture serial communication packets, or directly for network communications using any of the supported RS-485 protocols over a USB virtual COM port.
PLC-style logical, arithmetic and filtering data manipulation operations, called Database Logic, allow the construction of complex autonomous data conditioning and control functions. Additionally, a configurable network timeout action can be programmed to allow each database address its own unique "fail-safe" condition in the event of a network interruption. The gateway also supports a versatile Generic Serial communication driver which allows integration with any serial device including proprietary or custom protocols using ASCII and/or binary encoding formats.
The XLTR-1000 is a member of the ICC Millennium Gateway Series product family. Members of this family are designed to provide a uniform interface, configuration and application experience. This commonality reduces the user's learning curve, reducing commissioning time while simplifying support.
ANY combination of RS-485 protocol conversion is possible.
Some popular combinations include, but are NOT limited to the following:
- Modbus RTU to BACnet MS/TP
- Metasys N2 to BACnet MS/TP
- Siemens FLN to BACnet MS/TP
- Sullair to BACnet MS/TP
- M-Bus to Modbus RTU
- DMX-512 to Modbus RTU
- ASCII Serial to Modbus RTU
- ...and many more!
-
Brand
-
Network InterfaceRS-485, USB Virtual COM Port
-
RS-485 Ports2
-
USB Ports1
-
LED IndicatorsYes
-
Serial ProtocolsA.O. Smith AIN Slave, A.O. Smith PDNP Master, BACnet MS/TP Client, BACnet MS/TP Server, DMX-512 Master, DMX-512 Slave, Generic Serial Master, Generic Serial Slave, M-Bus Master, Metasys N2 Master, Metasys N2 Slave, Modbus RTU Master, Modbus RTU Slave, Modbus RTU Sniffer, MSA Chillgard Monitor, Siemens FLN (P1) Master, Siemens FLN (P1) Slave, Sullair Master, TCS Basys Master, Toshiba ASD Master, Toshiba Computer Link Master, USB Serial Sniffer Settings
-
Isolated RS-485No
-
Power Supply7 to 24VDC, USB
-
Field-UpgradeableYes
-
User Configuration InterfaceUSB
-
User Configuration Method
-
Configuration File Upload/DownloadYes
-
AlarmsNo
-
Network Timeout ActionYes
-
Mounting OptionsDesktop, DIN Rail, Panel/Wall
-
Mounting Hardware IncludedYes
-
Length3.000" (76.200 mm)
-
Width4.000" (101.600 mm)
-
Height1.380" (35.052 mm)
-
RoHS CompliantYes
-
CertificationsUL60950-1