ASD-MVETHERNET
Toshiba TOSVERT-300MVI Ethernet RS-485 option card.
EtherNet/IP, Modbus/TCP Industrial Ethernet and Modbus RTU RS-485 connectivity for Toshiba TOSVERT-300MVi drives.
This product has been discontinued and is no longer available for sale.
The ASD-MVETHERNET Multiprotocol Ethernet and Modbus RTU Interface allows information to be transferred seamlessly between a TOSVERT-300MVi drive and various fieldbus networks with minimal configuration requirements.
In addition to the connection to the ASD, the unit provides an Ethernet port, one RS485 port, and one RS232 port. The RS-485 port is a optically-isolated half-duplex 2-wire (A / B / Signal Ground / Shield) and allows a selection of various master and slave protocols. The RS232 port that can be used to configure the unit, update the internal firmware, upload/download files or act as a control protocol port. These various communication ports operate independently, and are configurable along with the unit's internal point database via the configuration tool.
The ASD-MVETHERNET provides an IEEE 802.3 10BASE-T/100BASE-TX Ethernet port. The Ethernet port accepts standard CAT5-type 8-conductor unshielded twisted-pair (UTP) patch cables and supports multiple protocols simultaneously.
The ASD-MVETHERNET supports a per-port and per-point 2-level configurable network timeout action that can be programmed to allow each internal point to have its own unique "fail-safe" condition in the event of a network interruption.
The ASD-MVETHERNET allows complex interchanges of data between otherwise incompatible networks. At the heart of the interface is an element called the "point database". The point database is entirely user-configurable, and provides the mapping information that allows requests from the various supported networks to be interpreted and stored in a common format. This allows data to be routed from any supported network to any other supported network.
- Rabbit Field Utility
- ASD-MVETHERNET Configuration Tool V1.1 - Prior to running the configuration tool, confirm that the device has been updated to the latest firmware version to ensure compatibility
-
Brand
-
Network InterfaceEthernet, RS-485
-
Ethernet Ports1
-
RS-485 Ports1
-
MMI Ports1
-
LED IndicatorsYes
-
Ethernet ProtocolsEtherNet/IP Server, Modbus/TCP Server
-
Serial ProtocolsModbus RTU Master, Modbus RTU Slave
-
Isolated RS-485Yes
-
Power SupplyASD
-
Field-UpgradeableYes
-
User Configuration InterfaceEthernet, RS-232
-
User Configuration MethodConfiguration Tool, Serial Console
-
Configuration File Upload/DownloadYes
-
AlarmsNo
-
Network Timeout ActionYes
-
Mounting OptionsInternal
-
Mounting Hardware IncludedYes
-
RoHS CompliantNo